Indevolt 集成可在 Home Assistant 与您的 Indevolt 储能设备之间建立直接的本地通信。

使用场景

通过此集成,您可以监控发电量、耗电量和电池状态,并配置功率限制及其他电池保护设置。

支持的设备

此集成支持以下设备:

  • BK1600/BK1600Ultra
  • SolidFlex/PowerFlex2000

先决条件

  1. Connect your Indevolt device and Home Assistant to the same local network.
  2. Ensure the Indevolt device is powered on and has acquired a network IP address. You can get the IP from the app or from your router.
  3. In the Indevolt app, enable the Local API and set the protocol to http.
配置

此集成可通过 UI 配置。前往 设置 > 设备与服务 添加。

Host:
  description: "您设备的 IP 地址。您可以在路由器或 Indevolt 应用中找到它。"

Indevolt 集成通过设备的标准 TCP 端口(8080)与设备通信。该端口会由 Home Assistant 自动使用,无需手动配置。

支持的功能

Indevolt 集成提供用于监控设备的传感器(只读)。

Sensors

BK1600/BK1600Ultra (Generation 1)

  • Device mode (overal setup of the device, for example standalone/cluster)
  • Energy mode (battery and energy management strategy, for example Self-Consumped Prioritized/Price-Based Strategy)
  • DC input power (2 channels, W)
  • Daily production (kWh)
  • Cumulative production (kWh)
  • Total AC input power (W)
  • Total AC input energy (kWh)
  • Total AC output power (W)
  • Total DC output power (W)
  • Battery power (W)
  • Battery charge/discharge state
  • Battery SOC (%)
  • Battery daily charging energy (kWh)
  • Battery daily discharging energy (kWh)
  • Battery total charging energy (kWh)
  • Battery total discharging energy (kWh)
  • Meter connection status
  • Meter power (W)

SolidFlex2000/PowerFlex2000 (Generation 2)

All Generation 1 sensors, plus:

  • Rated capacity (kWh)
  • DC input voltage (4 channels, V)
  • DC input current (4 channels, A)
  • DC input power (4 channels, W)
  • Grid voltage (V)
  • Grid frequency (Hz)
  • Bypass power (W)
  • Bypass input energy (Wh)
  • Off-grid output energy (kWh)
  • Total AC output energy (kWh)
  • Main battery serial number
  • Main battery SOC (%)
  • Main battery temperature (°C)
  • Main battery voltage (V)
  • Main battery current (A)
  • Battery pack 1-5 serial number
  • Battery pack 1-5 SOC (%)
  • Battery pack 1-5 temperature (°C)
  • Battery pack 1-5 voltage (V)
  • Battery pack 1-5 current (A)

可配置实体(仅限第二代)

除了上面列出的只读传感器外,Indevolt 集成还会为受支持的第二代设备公开以下可配置实体。您可以直接在 Home Assistant 中修改这些设置,它们会直接应用到设备上。

  • Energy mode: Configure battery and energy management strategy (select)
  • Discharge limit: Set the minimum battery level (emergency power/SOC, %)
  • Max AC output power: Configure maximum discharge power (W)
  • Inverter input limit: Set maximum PV input power (W)
  • Feed-in power limit: Configure grid feed-in power limit (W)
  • Allow grid charging: Enable or disable charging from the grid (switch)
  • Bypass socket: Enable or disable the bypass socket (switch)
  • LED indicator: Enable or disable the LED indicator (switch)

数据更新

Indevolt 集成会每 30 秒轮询一次 OpenData API,以自动从您的设备获取数据。如果更新失败,集成会在下一个设定间隔自动重试(自恢复)。

已知限制

  • 只有当设备不处于 "Outdoor / Portable" 模式时,才能设置 Energy mode
  • Some sensors are device generation-specific and may not appear for all models.
  • Some sensors / configurations available in the app are not (yet) available in the integration.

故障排除

无法添加设备或获取数据

  1. 确保设备已通电且运行正常。
  2. 确认设备和 Home Assistant 都连接在同一本地网络中。
  3. 确保设备 IP 地址正确且未发生变化。
  4. 检查 Indevolt 应用中的设备设置,确认 API 已启用。

更多信息请查看 Home Assistant 日志。

移除集成

此集成遵循标准集成移除流程。

To remove an integration instance from Home Assistant

  1. Go to Settings > Devices & services and select the integration card.
  2. From the list of devices, select the integration instance you want to remove.
  3. Next to the entry, select the three-dot menu. Then, select Delete.