Indevolt
Indevolt 集成可在 Home Assistant 与您的 Indevolt 储能设备之间建立直接的本地通信。
使用场景
通过此集成,您可以监控发电量、耗电量和电池状态,并配置功率限制及其他电池保护设置。
支持的设备
此集成支持以下设备:
- BK1600/BK1600Ultra
- SolidFlex/PowerFlex2000
先决条件
- Connect your Indevolt device and Home Assistant to the same local network.
- Ensure the Indevolt device is powered on and has acquired a network IP address. You can get the IP from the app or from your router.
- In the Indevolt app, enable the Local API and set the protocol to
http.
配置
此集成可通过 UI 配置。前往 设置 > 设备与服务 添加。
Indevolt 集成通过设备的标准 TCP 端口(8080)与设备通信。该端口会由 Home Assistant 自动使用,无需手动配置。
支持的功能
Indevolt 集成提供用于监控设备的传感器(只读)。
Sensors
BK1600/BK1600Ultra (Generation 1)
- Device mode (overal setup of the device, for example standalone/cluster)
- Energy mode (battery and energy management strategy, for example Self-Consumped Prioritized/Price-Based Strategy)
- DC input power (2 channels, W)
- Daily production (kWh)
- Cumulative production (kWh)
- Total AC input power (W)
- Total AC input energy (kWh)
- Total AC output power (W)
- Total DC output power (W)
- Battery power (W)
- Battery charge/discharge state
- Battery SOC (%)
- Battery daily charging energy (kWh)
- Battery daily discharging energy (kWh)
- Battery total charging energy (kWh)
- Battery total discharging energy (kWh)
- Meter connection status
- Meter power (W)
SolidFlex2000/PowerFlex2000 (Generation 2)
All Generation 1 sensors, plus:
- Rated capacity (kWh)
- DC input voltage (4 channels, V)
- DC input current (4 channels, A)
- DC input power (4 channels, W)
- Grid voltage (V)
- Grid frequency (Hz)
- Bypass power (W)
- Bypass input energy (Wh)
- Off-grid output energy (kWh)
- Total AC output energy (kWh)
- Main battery serial number
- Main battery SOC (%)
- Main battery temperature (°C)
- Main battery voltage (V)
- Main battery current (A)
- Battery pack 1-5 serial number
- Battery pack 1-5 SOC (%)
- Battery pack 1-5 temperature (°C)
- Battery pack 1-5 voltage (V)
- Battery pack 1-5 current (A)
可配置实体(仅限第二代)
除了上面列出的只读传感器外,Indevolt 集成还会为受支持的第二代设备公开以下可配置实体。您可以直接在 Home Assistant 中修改这些设置,它们会直接应用到设备上。
- Energy mode: Configure battery and energy management strategy (select)
- Discharge limit: Set the minimum battery level (emergency power/SOC, %)
- Max AC output power: Configure maximum discharge power (W)
- Inverter input limit: Set maximum PV input power (W)
- Feed-in power limit: Configure grid feed-in power limit (W)
- Allow grid charging: Enable or disable charging from the grid (switch)
- Bypass socket: Enable or disable the bypass socket (switch)
- LED indicator: Enable or disable the LED indicator (switch)
数据更新
Indevolt 集成会每 30 秒轮询一次 OpenData API,以自动从您的设备获取数据。如果更新失败,集成会在下一个设定间隔自动重试(自恢复)。
已知限制
- 只有当设备不处于 "Outdoor / Portable" 模式时,才能设置 Energy mode
- Some sensors are device generation-specific and may not appear for all models.
- Some sensors / configurations available in the app are not (yet) available in the integration.
故障排除
无法添加设备或获取数据
- 确保设备已通电且运行正常。
- 确认设备和 Home Assistant 都连接在同一本地网络中。
- 确保设备 IP 地址正确且未发生变化。
- 检查 Indevolt 应用中的设备设置,确认 API 已启用。
更多信息请查看 Home Assistant 日志。
移除集成
此集成遵循标准集成移除流程。
To remove an integration instance from Home Assistant
- Go to Settings > Devices & services and select the integration card.
- From the list of devices, select the integration instance you want to remove.
- Next to the entry, select the three-dot
menu. Then, select Delete.